LuxPAR Series

Our LuxPAR 20, 30, and 38 delivers the quality and quantity of light required for a broad range of recessed and down-lighting applications in a range of color temperatures and spot, narrow flood, and flood beams; dimming options are also available.

LuxPar 20

Dimmable E26 Base

Product Data Sheets

Dimmer Information

Beam Angle Part # Color Temperature (K) Center Beam Candle Power Light Output Color Rendering Download
Technical Documents
Spot15° LP20-031W27 Warm White 2700K 2200 275 85
LP20-031W29 Warm White 2900K 2350 285 85  
LP20-031W31 Warm White 3100K 2500 300 85  
LP20-031N41 Neutral White 4100K 3000 350 80  
Narrow Flood23° LP20-032W27 Warm White 2700K 1300 275 85  
LP20-032W29 Warm White 2900K 1400 285 85  
LP20-032W31 Warm White 3100K 1500 300 85
LP20-032N41 Neutral White 4100K 1800 350 80
Flood35° LP20-033W27 Warm White 2700K 600 275 85  
LP20-033W29 Warm White 2900K 650 285 85
LP20-033W31 Warm White 3100K 700 300 85
LP20-033N41 Neutral White 4100K 850 350 80  
CAUTIONS

Warning! Do Not Use LuxDot MR16 lamps on unregulated circuits susceptible to voltage spikes! Voltage spikes greater than 20V can severely damage the LuxDot and may cause a potentially unsafe lighting installation. Unregulated magnetic transformers are particularly susceptible to power surges and must be used in conjunction with regulating device.

Use only recommended transformers on LED Engin website,
PAR 20 Recommanded Dimmers

CAUTION - Risk of Electric Shock - Use IN Dry Locations Only. NOT FOR USE WHERE EXPOSED TO THE WEATHER.Not for use in totally enclosed recessed fixtures. This device is not intended for use with emergency exit fixtures or emergency exit lights.

LuxPar 30

Nondimmable E26 Base

Product Data Sheets

Dimmer Information

Beam Angle Part # Color Temperature (K) Center Beam Candle Power Light Output Color Rendering Download
Technical Documents
Narrow Flood23° LP30-062W27 Warm White 2700K 2275 525 85  
LP30-062W29 Warm White 2900K 2385 550 85  
LP30-062W31 Warm White 3100K 2535 585 85  
LP30-062N41 Neutral White 4100K 3000 690 80
Flood32° LP30-063W27 Warm White 2700K 1180 525 85  
LP30-063W29 Warm White 2900K 1250 550 85  
LP30-063W31 Warm White 3100K 1315 585 85  
LP30-063N41 Neutral White 4100K 1550 690 80
CAUTIONS

Warning! Do Not Use LuxDot MR16 lamps on unregulated circuits susceptible to voltage spikes! Voltage spikes greater than 20V can severely damage the LuxDot and may cause a potentially unsafe lighting installation. Unregulated magnetic transformers are particularly susceptible to power surges and must be used in conjunction with regulating device.

Use only recommended transformers on LED Engin website,
http://www.ledengin.com/luxdot/LuxDot_Transformer_Compatibility_List.pdf.

CAUTION - Risk of Electric Shock - Use IN Dry Locations Only. NOT FOR USE WHERE EXPOSED TO THE WEATHER.Not for use in totally enclosed recessed fixtures. This device is not intended for use with emergency exit fixtures or emergency exit lights.

LuxPar 38

Dimmable E26 base: xx=03

Nondimmable E26 base: xx=06

Dimmable GU24 base: xx=23

Nondimmable EGU24 base: xx=26

Product Data Sheets

Dimmer Information

Beam Angle Part # Color Temperature (K) Center Beam Candle Power Light Output Color Rendering Download
Technical Documents
Spot15° LP38-xx1W27 Warm White 2700K 4950 700 85  
LP38-xx1W29 Warm White 2900K 5300 750 85  
LP38-xx1W31 Warm White 3100K 6000 800 85  
LP38-xx1N41 Neutral White 4100K 6750 960 80
Narrow Flood23° LP38-xx2W27 Warm White 2700K 3300 700 85
LP38-xx2W29 Warm White 2900K 3525 750 85  
LP38-xx2W31 Warm White 3100K 4000 800 85
LP38-xx2N41 Neutral White 4100K 4500 960 80
Flood32° LP38-xx3W27 Warm White 2700K 1600 700 85
LP38-xx3W29 Warm White 2900K 1700 750 85  
LP38-xx3W31 Warm White 3100K 1900 800 85  
LP38-xx3N41 Neutral White 4100K 2200 960 80
CAUTIONS

Warning! Do Not Use LuxDot MR16 lamps on unregulated circuits susceptible to voltage spikes! Voltage spikes greater than 20V can severely damage the LuxDot and may cause a potentially unsafe lighting installation. Unregulated magnetic transformers are particularly susceptible to power surges and must be used in conjunction with regulating device.

Use only recommended transformers on LED Engin website,
http://www.ledengin.com/luxdot/LuxDot_Transformer_Compatibility_List.pdf.

CAUTION - Risk of Electric Shock - Use IN Dry Locations Only. NOT FOR USE WHERE EXPOSED TO THE WEATHER.Not for use in totally enclosed recessed fixtures. This device is not intended for use with emergency exit fixtures or emergency exit lights.